Confirm the new device ID code by sending
the Disarm signal from the same new Remote
Control or Remote Keypad within 15s as
follows…
Press on the Remote Control, or
Press
on the Remote Keypad.
The panel will produce three short beeps and
the LCD will show ‘Device Confirmed’.
The LCD will then show ‘Saving New Device’
while the ID code of the new detector is
stored into memory.
Deleting Linked Devices:
Scroll through the Zone menu until option ‘2.1
Remotes’ is displayed. The number of Remote
Controls/Keypads already linked will be shown,
(e.g. if there are two Remotes Controls and one
Remote Keypad linked the display will show
‘2.1 Remotes = 3’).
To delete all linked Remote Controls and Remote
Keypads press .
Press again within 15s to confirm and
actually delete all devices.
The display will now show ‘2.1 Remotes = 0’.
ALARM DURATION
Controls the alarm duration of the wireless, internal
control panel and wired sirens in the event of an
alarm, subject to the On/Off status of the wireless
and hard wired sirens which can be independently
controlled and disabled.
Scroll through the system menu until ‘2.2 Alarm
Time’ (and the current setting) is displayed.
Siren Duration
Default setting: 180 seconds
To change the setting press .
Enter the required Alarm Duration in units of
10 seconds (0 - 60).
e.g. enter 6 for a 60 seconds alarm duration.
minimum setting = 0. (i.e. 0 seconds / no
alarm).
maximum setting = 60 . (i.e. 600 seconds
or 10 minutes).
Press to save new setting and exit, or
Press to exit without saving.
Note: Following an alarm, the Siren will continue
to sound until either the system is Disarmed; or
the Alarm Duration time expires. If the ‘3 minute
alarm time limit’ of the Siren is enabled, then the
Siren will shut down after 3 minutes even if the
Control Panel siren is still sounding.
ENTRY/EXIT DELAY PERIOD
This sets the time entry and exit delay time period for
the system. The exit delay is the period between
arming the alarm and any detectors being allowed to
initiate an alarm (either instant or delayed). On
entering the property it sets the period between
triggering a detector configured as “delayed” and the
alarm occurring.
Default setting: 30 seconds
Scroll through the system menu until ‘2.3 Entry/Exit
Delay’ (and the current setting) is displayed.
Note: If the confirmation signal is not
received within 15s the control panel will
produce a single long beep and exit the
learning process. The learning process
will need to started again to learn the
new device into memory.
Note: If delete all is not confirmed within
15s then the action will be cancelled and
the Remote Controls/Keypads will not be
deleted and the display will revert to its
original setting.
,
Keypad User Access Code
? ? ? ?
1
1
1
ENTER
ENTER
ESC