Note: A maximum of 3 PIR or MAG detectors can be
linked to each alarm zone. A detector cannot be
linked to more than one zone.
Place the Control Panel into Learn Mode as follows:
With the system in Standby
P
ress
The Arm and Part-Arm LEDs will illuminate and
all Zone, Fire and tamper LEDs will flash
together.
1. To add/delete detectors on zone 1 press
and follow the process below
or for zone 2-6:
For zone 2 press and follow the
process below.
For zone 3 press and follow the
process below.
For zone 4 press and follow the
process below.
For zone 5 press and follow the
process below.
For zone 6 press and follow the
process below.
The Tamper LED will flash continuously to
indicate the system is in device Learn Mode.
The current number of PIR/MAG Detectors already
linked into zone 1/2/3/4/5 or 6 will be indicated on the
zone LEDs. For example if there are two detectors
linked, then zone LEDs 1 and 2 will be illuminated.
The panel will now listen for valid signals from new
PIR or MAG detectors to link to the zone.
To link a new PIR/MAG Detector to the
C
ontrol Panel:
2. Activate the Tamper Switch on the new
PIR/MAG detector.
If the detector is new and not already linked on
any security zone the panel will produce two
short beeps and the next available zone LED will
start flashing, (once every second).
3. Confirm the new device ID code activating the
Tamper Switch on the same new PIR/MAG
detector within 15 seconds.
The panel will produce three short beeps and
the zone LED will stop flashing and remain ON.
The ID code of the new PIR/MAG detector is
now stored in memory ready for saving.
4. Press to save new settings and return to
step1 or press to exit without saving.
5. If after adding a detector, no more detectors
require adding, then press to exit Learn
Mode.
To delete linked PIR/MAG Detectors from a
zone on the Control Panel:
1. Follow step 1 in Learn Mode if not already
entered.
2. Press
All illuminated zone LEDs indicating linked
devices will start flashing, (once every second).
LEARNING ZONE DETECTORS
17
?
?
??
ENTER
,
,
User Access Code
1
2
1
3
1
4
1
5
1
6
Note: The Panel will remain in Learn Mode for
30s. If a valid signal is not received from a
PIR/MAG within 30s it will automatically exit
Learn Mode and return to the top level of
Program Mode..
Note: If the detector is already linked to the
control panel (on any zone) or if there are
already the maximum 3 detectors linked to
the specific alarm zone then the panel will
produce a single long beep received signal
from the detector will be ignored.
Note: If the confirmation signal is not received
within 15s the flashing LED will stop flashing
and turn off. The panel will exit to the top level
of Learn Mode without saving any changes.
The learning process will need to start again to
learn the new device into memory.
ENTER
ESC
ESC
1
1