Response SA1 E Betriebsanleitung Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
22
PIR Movement Detector false alarming.
1. Ensure that the detector is not pointing at a source
of heat or a moving object.
2. Ensure that the detector is not mounted above a
radiator or heater.
3. Ensure that the detector is not facing a window or in
direct sunlight.
4. Ensure that the detector is not in a draughty area.
5. Sensitivity set too HIGH – reset to LOW sensitivity,
(i.e. DIP 5 of SW3 OFF).
PIR Movement Detector not detecting a person’s
movement.
1. Ensure the battery clip is securely connected.
2. Ensure ‘House Code’ is correctly set to the same
code as all other system devices.
3. Sensitivity set too LOW – reset to HIGH sensitivity,
(i.e. DIP 5 of SW3 ON).
4. Ensure DIP switches 1, 2 and 3 of SW3 are
correctly set, (i.e. 1=ON, 2=ON, and 3=OFF).
5. Ensure that detector is mounted the correct way up,
(i.e. with detection window at the bottom).
6. Ensure that the detector is mounted at the correct
height, (i.e. 2 - 2.5 metres).
7. Allow up to 3 minutes for detector to stabilize and
become fully operational. Leave the area for this
period.
8. Ensure detector is within effective radio range of
the Siren and is not mounted close to metal objects
which may interfere with the radio transmission.
PIR Movement Detector LED ashes on detection
of movement, (device in Normal Operation mode).
1. Ensure that the detector is congured for normal
operation, (i.e. DIP switch 4 of SW3 is OFF).
2. Low battery - Replace battery.
Magnetic Contact Detector not working.
1. Ensure that Magnet is correctly positioned in
relation to Detector and that the gap between
magnet and detector is less than 10mm.
2. Ensure batteries are tted with correct polarity.
3. Ensure battery holder connections are making good
contact with the batteries and PCB (Circuit board).
4. Ensure ‘House Code’ is correctly set to the same
code as all other system devices.
5. Ensure DIP switches 9, 10 and 11 are correctly set,
(i.e. 9=ON, 10=ON, and 11=OFF).
6. If there is no additional wired Magnetic Contact
connected ensure jumper link is tted.
7. If an additional wired Magnetic Contact is
connected:
a. Ensure jumper link is removed.
b. Check that both contacts are closed.
c. Check that additional contact is correctly wired.
Note: If a wired contact is used, both protected
doors / windows must be closed when the system
is armed (otherwise neither door/window will be
protected).
8. Ensure detector is within effective radio range of
the Siren and is not mounted close to metal objects
which may interfere with the radio transmission.
Magnetic Contact Detector false alarming.
1. Ensure that Magnet is correctly positioned in
relation to Detector.
2. Ensure that gap between Magnet and Detector is
less than 10mm.
3. Tamper switch below battery cover not depressed
– check battery cover is tted correctly and that
xing lugs are not broken.
LED on Magnetic Contact Detector illuminating
when door or window is opened.
1. Low battery - replace batteries.
HELPLINE
If you have any problems with your alarm, please
call the Helpline on:
01268 563273
(Lines open 9.00am to 5.00pm, Monday to Friday)
Seitenansicht 21
1 2 ... 17 18 19 20 21 22 23 24

Kommentare zu diesen Handbüchern

Keine Kommentare