1. Undo and remove the xing screw from the bottom
edge of the Keypad and remove the wall mounting
plate.
2. Using the mounting plate as a template, mark the
positions of the two xing holes on the wall. A small
spirit level will ensure it is perfectly level.
The Keypad is powered by a PP3 Alkaline battery
which under normal conditions will have an expected
life of approximately 1 year. When the battery level
drops, the “LOW BATT” LED on the front of the Keypad
will ash. When this occurs the battery should be
replaced as soon as possible.
POSITIONING THE KEYPAD
The Keypad is suitable for mounting in dry interior
locations only.
The Keypad should be located within a protected area
so that it cannot be reached by an intruder without
opening a protected door or passing through an area
protected by a PIR Movement Detector.
The Keypad should be mounted in a position close to
the main entrance door so that the User Access Code
can be entered and the alarm system shut down within
the 15 seconds entry time period.
Note: DO NOT x the Keypad onto or very close to
metalwork (e.g. radiators, water pipes, etc) as this
could affect the radio range of the device.
INSTALLING AND CONFIGURING THE
KEYPAD
Note: If adding a Keypad to an installed system,
ensure that the Siren is in Service Mode before
commencing installation, (see page 19). Remember
to switch the Siren back to Operating Mode after
installation is complete, (see page 19).
3. Fix the mounting plate to the wall using the two
18mm No.4 screws and 22mm wall plugs as required,
(a 5mm hole will be required for the wall plugs). Do not
over-tighten the screws as this may distort or damage
the mounting plate.
Note: The wall plugs supplied with the product are not
suitable for plasterboard walls, if mounting the Keypad
onto plasterboard use appropriate wall plugs.
4. Undo and remove the four xing screws in the rear
of the Keypad and remove the rear cover.
5. Located on the circuit board above the battery clip is
a row of 8 DIP switches. These switches set the House
Code for the Keypad and must be set to the same
ON/OFF combination as the DIP switches in all other
system devices.
6. Ensure that the jumper link located in the top left
corner of the circuit board is removed for use with this
alarm system, the link can be discarded.
7. Connect the PP3 alkaline battery to the battery clip.
8. Replace the rear cover and ret xing screws. Do
not over-tighten the xing screws.
9. Ret and secure the Keypad onto the wall mounting
plate. Do not over-tighten the xing screw.
Note: The Keypad is supplied with a User Access Code
of: “1234”. For security reasons, this code should be
changed to another 4 digit number which only you and
other users of the system should know.












Seitenansicht 7