FACTORY SETTINGS
USER CODE SETUP
Master User: 1234
Users 1-6: Not programmed
Duress Code: Not programmed
SYSTEM SETUP MENU
Alarm Duration: 3 minutes
Entry/Exit Delay period: 30s
Entry Delay Beeps: On
Exit Delay Beeps: On
Wireless Siren: On
Wired Siren: Off
Auxiliary Relay: Off
Jamming Detection: Off
Zone Lockout: On
Time: 12:00
Date: 01/01/07
Dial Mode: Off
Remote Phone Access: Off
Rings To Answer Phone: 6
REMOTE MANAGER SETUP
Phone Numbers 1 and 2: Not programmed
System ID Code: Not programmed
VOICE DIALLER SETUP MENU
Phone Numbers 1-4: Not programmed
Messages: Not programmed
ZONE SETUP MENU
Zone defaults set according to detector type
identified during learning process:
PIR/MAG Detectors
Zone Name: No name
Zone Type: Intruder
Zone Mode: Zones 1-2: Delayed
Zones 3-36: Instant
Part-Arm 1: Zones 1-4: On
Zones 5-36: Off
Part-Arm 2: Off
Chime: Off
Smoke Detectors
Zone Name: No name
Zone Type: Fire
Zone Mode: Instant
Part-Arm 1: Off
Part-Arm 2: Off
Chime: Off
FACTORY SETTINGS
LATCH KEY SETUP
Status: OFF
Selected User Setup: OFF (all users)
Phone Numbers: Not programmed
ANSWER PHONE SETUP
Status: OFF
User status: All Off
User ID messages: Not recorded
Phone Numbers: Not programmed
SPECTRA LIGHTING SETUP
Set Light-On Period: 3 Minutes
Spectra Mode: OFF
Stop Time: 06:00
Start Time: 18:00
RESET FACTORY SETTINGS
1. Press
This puts the system into Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
3. Remove the DC power jack, then remove and
disconnect one of the back-up batteries.
4. Set jumper link P1 to the ON position.
5. Reconnect the power supply jack.
6. The Control Panel will now reset itself with all
factory settings.
‘EEPROM RESET’ will be displayed while the
factory settings are restored to memory. Once
the memory reset has been completed ‘DISARM
READY’ will be displayed.
7. Reconnect and replace the back-up battery.
8. Reset jumper link P1 into the OFF position.
9. Close the Control Panel cover and refit the fixing
screws.
?
?
??
ENTER
, ,
User Access Code
OFF ON
Jumper Link