ENSURE THAT THE CONTROL UNIT IS STILL IN
TEST MODE.
1. Remove the battery cover by sliding it down
and pulling it forward. DO NOT USE A SCREW
DRIVER.
2. Using a ball-point pen, set the miniature switches
1-6 inclusive to the pre-determined House Code.
3. Determine the Zone on which each Detector is
to operate and set miniature switches 7 and 8 to
correspond to the required Zone. (Refer to
System Zoning page 9).
4. Fit the 9 volt alkaline battery supplied to the
battery terminals.
Note: As soon as the battery is connected, a
two-tone chime will be emitted from the Control
Unit siren and the appropriate Zone LED will
flash for 3 seconds. This confirms that the
‘House Code’ and Zoning is correct.
5. With the battery cover off, hold the Detector at
the proposed installation position, press and
release the anti-tamper microswitch. Providing
the proposed location is within radio range of the
Control Unit, the two-tone chime will be repeated.
After the battery has been connected for approx 60
seconds the Infra Red Detector will become active
causing the Control Unit to give a two-tone chime
every time movement is detected.
6. Leave the battery cover off, remove the battery
and proceed to mount the Detector as described.
7. Leave the Control Unit in Test mode.
MOUNTING THE WIRELESS PASSIVE
INFRA RED DETECTOR(S)
1. Remove the screw (in the battery compartment)
holding the wall bracket to the Detector.
2. Slide the bracket down and remove the wall
bracket from the Detector as shown.
3. Hold the wall bracket in position and mark the two
mounting holes. (For corner mounting drill pilot
holes in the wall bracket chamfers as shown).
4. Drill two 4mm diameter holes and insert the
plastic wall plugs supplied.
5. Screw the wall bracket to the wall using the
screws supplied.
6. Position the Detector on the locating pin and slide
down, then fix the Detector to the wall bracket
using the holding screw.
Note: The normal detector mounting position is with
the battery compartment downwards. However, if the
detector is fitted in a room where pets have access,
mount the Detector with the battery compartment
upwards at a height of 1m from the floor. This will
shorten the detection range but allow pets to move
about the floor area without activating the Detector.
TESTING THE WIRELESS PASSIVE
INFRA RED DETECTOR(S)
ENSURE THAT THE CONTROL UNIT IS STILL IN
TEST MODE.
1. Refit the battery in the Detector but do not replace
the cover. The Control Unit will emit a two-tone
chime and the Detector LED will illuminate for a
60 second ‘warm up’ period.
2. During the ‘warm up’ period, leave the protected
area and ensure that no movement takes place in
this area for at least 60 seconds. Now, by walking
into the protected area the Detector LED will flash
and the Control Unit will emit a two-tone chime
each time the Detector senses movement. This
‘Walktest’ facility will enable you to check that
movement can be detected in all areas of the room.
3. Once the detection range has been verified, refit
the battery cover ensuring that the battery lead
wires are not trapped in the process.
RE5000S Professional Alarm System 11