FURTHER TEST:
1. When the battery cover is fitted, once again leave
the protected area and ensure that no movement
takes place for at least 60 seconds.
2. Walk into the protected area. The Control Unit
will emit a two-tone chime.
Note: When the Detector is fully installed, ie. battery
cover is refitted, the unit will not detect movement for
approximately 60 seconds after each activation. In
normal operation, with the battery cover on, the red
LED below the detector window will not illuminate
upon detection of movement.
Leave the Control Unit in Test Mode and proceed to
install your remaining detectors.
FITTING THE STANDARD
MAGNETIC CONTACT
DETECTOR(S)
One standard Magnetic Contact Detector is supplied
in the RE5000S package. However, additional Magnetic
Contact Detectors can be purchased separately if
required. Any number of Magnetic Contact Detectors
can be used with your system providing they are all
coded with the system House Code and are within radio
range of the Control Unit. Magnetic Contact Detectors
can be fitted to protect doors or windows, as required.
To set the House Code and fit the battery, proceed
as follows:
ENSURE THAT THE CONTROL UNIT IS STILL IN
TEST MODE.
1. Remove the battery cover by sliding it off. DO
NOT USE A SCREW DRIVER.
2. Set the miniature switches 1 to 6 inclusive to the
pre-determined House Code.
3. Determine the Zone on which the Detector is to
operate and set miniature switches 7 and 8 to
correspond to the required Zone. (Refer to System
Zoning page 9).
4. Fit the 12 volt alkaline battery supplied with the
negative towards the battery spring.
Note: As soon as the battery is fitted, a two-tone
chime will be emitted from the Control Unit siren
and the appropriate Zone LED will flash for 3
seconds. This confirms that the House Code
and Zoning is correct.
12 RE5000S Professional Alarm System