general use of the system to be via this second code
(eg. for children, guests, cleaners etc) and to retain
the Main User Access Code for your personal use in
re-programming the system. To change the Main
User Access Code:-
With the Control Unit in programming mode Enter
. No Zone LED’s will be illuminated.
Enter your new Access Code.
The Zone LED’s 1-4 will illuminate as each digit is entered.
Press to memorise the setting and to revert to
Programming mode.
6. DOOR-CHIME ZONE
It is possible to programme the Control Unit to emit a
two-tone ‘door-chime’ tone when a Magnetic Detector
is opened, with the system in Disarmed mode. This
facility may therefore be used to monitor Entry/Exit
doors when the system is not armed. The facility is
Zonal, ie: if there are 2 Magnetic Detectors on one
Zone, both detectors will operate the chime tone. It is
not possible to use PIR Detectors or the Zone 6 Hard
Wired input to generate the chime tone.
To set the Zone(s) on which the chime will operate
make a note of the Zone of the appropriate magnetic
detector(s) and proceed as follows:-
With the Control Unit in Programming mode Enter
. The Zone LED’s 1-6 will indicate the
status of each Zone:-
Zone LED ‘ON’ = Door-Chime ‘ON’ Zone
Zone LED ‘OFF’ = Door-Chime ‘OFF’ Zone
Factory default:-
Zone 1 Door-Chime ‘ON’
Zone 1 LED ‘ON’.
To add or delete a door-chime Zone press the
number of the Zone to illuminate or extinguish the
appropriate Zone LED.
Press to memorise the setting and to revert to
the Programming mode.
7. ENTRY DELAY TIME
When entering an entry delay Zone with the system
Armed or Part Armed, the system will be inactive for a
preset Entry Delay time to allow you time to disarm
the system by entering your access code at the
Control Unit, or using the Remote Control.
During the entry delay period, the Control Unit
sounder will emit an intermittent bleep tone and the
appropriate Zone LED(s) will flash to indicate that the
system has been triggered by a delay Zone detector.
With the Control Unit in Programming mode, Enter
.
A Zone LED will illuminate to indicate the setting
Factory default:-
30 seconds - Zone 3 LED ‘ON’.
To change the setting press the appropriate key to
illuminate the associated Zone LED:-
Press to memorise the setting and to revert to
the Programming mode.
8. PART ARM ZONE OMIT
Any of the Zones 1-6 can be omitted (ie inactive)
when the system is Part Armed. This will enable you
to arm only the selected (active) Zones when you Part
Arm the system.
With the Control Unit in Programming mode Enter
the Zone LED’s 1-6 will illuminate to
indicate the Zones which are omitted (inactive) when
the system is Part Armed:-
Factory default:-
Zone 1 omitted - Zone 1 LED ‘ON’.
To add or delete an omitted Zone, press the number
of the Zone to illuminate or extinguish the appropriate
Zone LED.
Press to memorise the setting and to revert to
the Programming mode.
RE5000S Professional Alarm System 17