thereby ensuring that the signal is correctly
received. For full details of the setting and operation
of the optional Medical Alert Pendant refer to the
instructions supplied with the unit.
To programme the Siren Code into the Control Unit,
with the Control Unit in Programming mode Enter
. The Zone LEDs 1-8 will
indicate the Siren Code switch setting selected for
each 2 position switch as follows:-
Switch set ON - Zone LED ON
Switch set OFF - Zone LED OFF
Factory default:-
All switches set to ON - all LEDs ON.
To enter/change the Siren Code, refer to the miniature
switch 1-8 settings previously set in your Solar Siren
& Strobe (and /or Medical Alert Pendant(s) and enter
the setting of each switch in turn as follows:-
For switch set ON press
For switch set OFF press
For example; for Siren Code:-
The Zone LEDs 1-8 will indicate the new Siren Code
switch setting selected for each switch 1-8 as
follows:-
switch ON - LED ON
switch OFF - LED OFF
Press to memorise the Siren Code setting and
to revert to the programming mode.
13. SECOND USER ACCESS CODE
The Control Unit is supplied with a Preset Second
User Access Code of .
This code allows Arming/Part Arming and
Disarming only at the Control Unit and may
therefore be entrusted to children, guests or
neighbours; or alternatively this code could be
used for day to day operation, with the Main User
Access Code reserved for re-programming only.
However you plan to use the system, for security
reasons it is essential that you change the Second
User Access Code to another four digit number
which only you and other users of the system will
know and use. (Again, a number with a personal
significance will be easier to remember).
With the Control Unit in Programming mode Enter
.
No Zone LEDs will be illuminated.
Enter your new Second User Access Code.
The Zone LEDs 1-4 will illuminate as each digit is
entered.
Press to memorise the setting and to revert to
the Programming mode.
Programming of your Control Unit is now
complete. Exit Programming mode by pressing
again.
EXTERNAL CONNECTIONS
The Control Unit incorporates a terminal block and
Communication Interface Cable to facilitate external
connection of a Hard-wired Siren, Telephone
Dialler/Communicator, or a Hard-wired Zone 6 Trigger
input. Before making any connections, ensure that
the memory link is in the ON position and then
remove all power (mains and back up battery).
Note: Any unused cores of the interface cable must
be cut back; insulated or made safe to prevent
short circuits.
After making your external connections reconnect the
power supply and back-up battery and refit the
Control Unit to its wall fixing bracket.
Wiring interconnections should comply with the
appropriate requirements of BS4737 part 1 in respect
of cable type and installation methods.
Full details of the Control Unit terminal block
connections and Communicator Interface Cable
connection are shown overleaf:-