Seitenansicht 24
25
(Optional)
The Control Panel incorporates a terminal block for
connection of a Hard-wired Siren. The connection
terminal block is located inside the Control Panel
behind the front cover. To access the terminal block
you must first put the system into Test Mode to
prevent an alarm occurring.
To do this:
Press
Undo the two fixing screws on the top edge of the
Control Panel and open the front cover.
Before making any connections, ensure that the
Reset Jumper Link P1 is in the ‘OFF’ position and
then remove the DC power jack and disconnect 1 of
the back-up batteries.
The signalling contacts on all hardwired alarm and
tamper zones must be volt free. (i.e. they must only
open and close and not apply any self generated
voltage across the contacts).
The contacts on zones 33, 34, 35 and the tamper
circuit should be normally closed. An alarm will be
triggered when the contacts open. On zones 33, 34
and 35, additional Wired Magnetic Door/Window
Contact Detectors can be hardwired to these
terminals (by purchasing the Response Wired
Door/Window Contact Accessory Pack (PW1).
The contacts on zone 36 should be normally open.
An alarm will be triggered when the contacts close.
Note: The External Tamper Switch jumper link P51
should be fitted into the ON position only if the
hardwired tamper circuit is used, otherwise it must
be in the OFF position.
After making your external connections reconnect
the power supply and back-up Battery. Then close
the Control Panel cover and tighten the fixing
screws on the top edge.
Press to leave Test Mode and return to Standby.
EXTERNAL CONNECTIONS
T1 T2 GND T3 T4 N.C. CN.O.GNDGND BUZ BUTTAMP GND B+ V+ OUT GND
Permanent
12Vdc power
supply output
(100mA max.)
Latching
relay contacts
(volt-free)
Hardwired Zone
Connections
(using normally
closed contacts)
Switched 12Vdc
output for
wired Siren
(300mA max.)
T1
T2
GND
T3
T4
N.C.
C
N.O.
GND
GND
TAMP
GND
B+
V+
OUT
GND
Tamper circuit
connections for
wired Siren
Not Used
Terminal Block
External Tamper
Switch Jumper
Link P51
Reset Jumper
Link P1
TERMINAL BLOCK DETAIL
OFF ON
Jumper Link
Reset Jumper Link P1
Jumper Link
1
4
23
ENTER
, ,
User Access Code
ESC